Trident IoT Zigbee SDK
Loading...
Searching...
No Matches
Power Configuration server Callbacks
Collaboration diagram for Power Configuration server Callbacks:

Functions

void tr_power_configuration_server_init_cb (zb_uint8_t endpoint)
 Callback fires when the Power Configuration server cluster plugin is initialized.
zb_bool_t tr_power_configuration_server_command_received_cb (zb_zcl_parsed_hdr_t *cmd_info)
 Callback that user can declare to handle any Power Configuration server commands.
void tr_power_configuration_server_write_attr_cb (zb_uint8_t endpoint, zb_uint16_t attr_id, zb_uint8_t *new_value, zb_uint16_t manuf_code)
 Callback fires when an Power Configuration server attribute is about to be written.
void tr_power_configuration_server_battery_alarm_state_changed_cb (zb_uint8_t endpoint, zb_uint32_t batt_alarm_state)
 Callback fires when the power configuration server battery alarm state attribute is changes.
zb_bool_t tr_power_configuration_server_pre_alarm_send_cb (zb_uint8_t endpoint, zb_uint8_t alarm_code)
 Callback fires when the power configuration server is about to send an alarm.

Detailed Description



Function Documentation

◆ tr_power_configuration_server_battery_alarm_state_changed_cb()

void tr_power_configuration_server_battery_alarm_state_changed_cb ( zb_uint8_t endpoint,
zb_uint32_t batt_alarm_state )

Callback fires when the power configuration server battery alarm state attribute is changes.

Parameters
endpointdevice endpoint
batt_alarm_statenew battery alarm state value

◆ tr_power_configuration_server_command_received_cb()

zb_bool_t tr_power_configuration_server_command_received_cb ( zb_zcl_parsed_hdr_t * cmd_info)

Callback that user can declare to handle any Power Configuration server commands.

Parameters
cmd_infostruct that contains zcl header info
Returns
ZB_FALSE to allow framework to continue processing the command

◆ tr_power_configuration_server_init_cb()

void tr_power_configuration_server_init_cb ( zb_uint8_t endpoint)

Callback fires when the Power Configuration server cluster plugin is initialized.

Parameters
endpointdevice endpoint being initialized

◆ tr_power_configuration_server_pre_alarm_send_cb()

zb_bool_t tr_power_configuration_server_pre_alarm_send_cb ( zb_uint8_t endpoint,
zb_uint8_t alarm_code )

Callback fires when the power configuration server is about to send an alarm.

Parameters
endpointdevice endpoint
alarm_codealarm code to be sent
Returns
ZB_FALSE to allow framework to continue sending the alarm

◆ tr_power_configuration_server_write_attr_cb()

void tr_power_configuration_server_write_attr_cb ( zb_uint8_t endpoint,
zb_uint16_t attr_id,
zb_uint8_t * new_value,
zb_uint16_t manuf_code )

Callback fires when an Power Configuration server attribute is about to be written.

Parameters
endpointdevice endpoint
attr_idZCL attribute id
new_valuepointer to the new attribute value